Sphygmomanometers for Clinical Use Ambulatory Blood Pressure Measurement Protocols & Standards General Papers relating to Blood Pressure Measurement

Automated Sphygmomanometers for Self-measurement of Blood Pressure

General Papers on SBPM
Specific SBPM Sphygmomanometers
- Upper Arm Devices for Self Measurement
- Wrist Devices for Self Measurement
- Finger Devices for Self-measurement
Devices for Measuring Blood Pressure in the Community

General Papers on SBPM

O'Brien E. What's new in blood pressure measurement? A workshop of the European Society of Hypertension. Blood Pressure Monitoring 2004, 9:281–282 (pdf)
Proceedings of the European Society of Hypertension Working Group on Blood Pressure Monitoring Scientific Workshop: What's New in Blood Pressure Measurement? Paris, France on 17th June 2004.
 
George Stergiou, Thomas Mengden, Paul L Padfield, Gianfranco Parati, Eoin O'Brien and working group on blood pressure monitoring of the European Society of Hypertension Self monitoring of blood pressure at home. BMJ 2004, 329:870-871(pdf)
 
Ohkubo T, Asayama K, Kikuya M, Metoki H, Obara T, Saito S, Hoshi H, Hashimoto J, Totsune K, Satoh H, Imai Y. Prediction of ischaemic and haemorrhagic stroke by self-measured blood pressure at home: the Ohasama study. Blood Press Monit 2004;9:315-320
 
Mengden T, Ewald S, Kaufmann S, vor dem Esche J, Uen S, Vetter H. Telemonitoring of blood pressure self measurement in the OLMETEL study. Blood Press Monit 2004;9:321-325
 
Chiolero A, Gervasoni JP, Rwebogora A, Mkamba M, Waeber B, Paccaud F, Burnier M, Bovet P. Discordant prevalence of hypertension using two different automated blood pressure measurement devices: a population-based study in Dar es Salaam (Tanzania) Blood Press Monit 2004;9:59-64
 
O'Brien E, Atkins N, Mee F, O'Malley K.� Evaluation of blood pressure measuring devices.� Clin & Exper Hypertension 1993;15(6):1087-1097
 
Ng K-G, Small CF. Survey of Automated Noninvasive Blood Pressure Monitors. J Clin Eng 1994;19:452-475
 
Rithalia SVS, Edwards D. Comparison of oscillometric and intra-arterial blood pressure and pulse measurement. J Med Engin Tech 1994;18:179-181.
 
Ng K-G. Automated Noninvasive blood pressure measurement. Intensive Care World 1995;12:89-102
 
Livi R, Teghini L, Cagnoni S, Scarpelli PT. Simultaneous and Sequential Same-Arm Measurements in the Validation Studies of Automated Blood Pressure Measuring Devices. Am J Hypertens 1996;9:1228-1231
 
Dieterle T, Battegay E, Bucheli B, Martina B. Accuracy and 'range of uncertainity' of oscillometric blood pressure monitors around the upper arm and wrist. Blood Pressure Monitoring 1998;3:339-346
 
Rogers P, Burke V, Stroud P, Puddey IB. Comparison of oscillometric blood pressure measurements at the wrist with an upper-arm auscultatory mercury sphygmomanometer. Clin & Exper Pharmacol & Pharmacol 1999;26:477-481
 
Natarajan P, Shennan AH, Penny J, Halligan AW, de Swiet M, Anthony J. Comparison of auscultatory and oscillometric automated blood pressure monitors in the setting of preeclampsia. Am J Obstet� Gynecol 1999;181:1203-1210
 
Kikuya M, Chonan K, Imai Y, Goto E, Ishii M on behalf of the Research Group. Accuracy and reliability of wrist-cuff devices for self-measurement of blood pressure. J Hypertens 2002;20:629-638
 
Longo D, Toffanin G, Bertolo O, Frezza P, Palatini P. Blood pressure measured at the wrist overestimates blood pressure measured at the arm. J Hypertens 2002; 20 (suppl 4) :S230
 

Types of Sphygmomanometers for Self Measurement

Wrist devices
Mourad A, Gillies A, Carney S. Inaccuracy of wrist-cuff oscillometric blood pressure devices: an arm position artefact? Blood Press Monit 2005; 10 :67-71
 
Palatini P, Longo D, Toffanin G, Bertolo O, Zaetta V, Pessina AC, Wrist blood pressure overestimates blood pressure measured at the upper arm. Blood Press Monit 2004;9:77-81
 

Specific SBPM Sphygmomanometers

Upper Arm Devices for Self Measurement

A & D Takeda
 
 
UA-631 (UA-779)
  Longo D, Bertolo O, Toffanin G, Frezza P, Palatini P. Validation of the A & D UA-631 (UA-779 Life Source) device for self-measurement of blood pressure and relationship between its performance and large artery compliance. Blood Press Monit 2002;7:243-248
 
 
UA-704
Koblava ZD, Kotovskaya YV, Rodionov E Validation of semi-automatic device UA-704 for self-measurement of blood pressure Blood Press Monit 2005; 10 :223-225
   
 
UA-705
Verdecchia P, Angeli F, Gattobigio R, Angeli E, Pede S, Pittavini L. Validation of the A&D UA-705 device for self-measurement of blood pressure according to the British Hypertension Society protocol Blood Press Monit 2006; 11 :223-227
 
 
UA-767
  Davis P D, Dennis J L and Railton R. Evaluation of the A&D UA-767 and Welch Allyn Spot Vital Signs noninvasive blood pressure monitors using a blood pressure simulator. Journal of Human Hypertension 2005;3:197-203
   
  Rogoza AN, Pavlova TS, Sergeeva MV. Validation of A & D UA-767 device for the self-measurement of blood pressure. Blood Press Monit 2000;5:227-231
 
  Yarrows SA, Brook RD. Measurement Variation Among 12 Electronic Home Blood Pressure Monitors. Am J Hypertens 2000;13:276-282
 
 
UA-774 (UA-767 Plus)
  Verdecchia P, Angeli F, Poeta F, Reboldi GP, Borgioni C, Pittavini L, Porcellati C. Validation of the A&D UA774 (UA-767Plus) device for self measurement of blood pressure. Blood Press Monit 2004;9:225-229
   
  Kobalava ZD, Kotovskaia IV, Rusakova OS, Babaeva LA. Validation of UA-767 Plus device for self measurement of blood pressure Clin. Pharmacol. Ther. 2003;12 (2):70-72
   
 
UA-787
  Longo D, Toffanin G, Garbelotto R, Zaetta V, Businaro L, Palatini P. Performance of the UA-787 oscillometric blood pressure monitor according to the European Society of Hypertension Protocol. Blood Press Monit 2003;8:91-95
 
Artsana 610
Pini C, Pastori M, Baccheschi J, Omboni S, Parati G. Validation of the Artsana CSI 610 automated blood pressure monitor in adults according to the International Protocol of the European Society of Hypertension Blood Pressure Monitoring 2007;12:179–184
 
Assure 605
Yarrows SA, Brook RD. Measurement Variation Among 12 Electronic Home Blood Pressure Monitors. Am J Hypertens 2000;13:276-282
 
Bard Medical Sentron
Zambanini A, Cox A, McIntosh C, Feher M. A comparison of semi-automated BP monitors in diabetic patients. J Hypertens 2000;18(suppl 4):S121 (Abstract)
 
Boso carat
Eckbert S, Kemper B, Horstkotte D. How accurate are devices for blood pressure self-measurement at the upper arm, wrist and finger in young normotensive patients and elder hypertensive patients? J Hypertens 2001;19(suppl 2):S24 (Abstract)
 
Braun Vital-Scan (BVS) BP Monitor
Nolly H, Romero M, Nolly A, Nolly M. Home blood pressure (BP) measurement using B.P. Braun Vitalscan monitor. J Hypertens 200;18(supp 4):S119
 
Colson MAM BP3AA1-2
Pereira T, Maldonado J. Valida çã o de aparelho de medi çã o autom á tica da press ã o arterial Colson MAM BP3AA1-2 segundo o Protocolo da Sociedade Europeia de Hipertens ã o Rev Port Cardiol 2005;24(11):1341-1351
 
Health & Life
 
HL-868BA
  Chen HE, Cui Y, Sheng CS, Li LH, Li Y, Wang JG. Validation of the Health & Life HL868BA blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol. Blood Press Monit 2008;13:305-308
 
  Chen HE, Cui Y, Sheng CS, Li LH, Li Y, Wang JG. Validation of the Health & Life BSP-4007 blood pressure monitor in adult Chinese according to the European Society of Hypertension International Protocol J Hypertens 2008;26 (suppl. 1):S496 (Abstract PS35/TUE/07)
 
 
HL-888HA
  de Greeff A, Shennan AH. The Health and Life device (HL888HA): accuracy assessment in an adult population according to the British Hypertension Society protocol Blood Pressure Monitoring 2007;12:107-111
 
  Tholl U, Assouline E. Validation of the automatic arm type non-invasive blood pressure monitor HL-888HA J Hypertens 2006; 24 (suppl 4):S285 Abstract P14.496
 
IEM Stabil-O-Graph
Westhoff T, Schmidt S, Zidek W, van der Giet M. Validation of the Stabil-O-Graph® Blood Pressure Self-Measurement Device According to BHS and ESH Criteria Journal of Hypertension 2006; 25 (suppl 2) S161
 
Oever GHM ten, Bour J, Cortez-Campeao, van de Kerkhof HM, Wolf A. Validation of Stabil-O-Graph device for self-measurement of blood pressure monitoring according to the British Hypertension Society (BHS) standards and protocol [dabl® Educational Trust regrets that full details are missing] (Abstract)
 
Healthcheck CX-5
O'Brien E, Mee F, Atkins N, O'Malley K.� Inaccuracy of seven popular sphygmomanometers for home-measurement of blood pressure.� J Hypertens 1990;8:621-634
 
Lumoscope1085M
Yarrows SA, Brook RD. Measurement Variation Among 12 Electronic Home Blood Pressure Monitors. Am J Hypertens 2000;13:276-282
 
Microlife
 
BP 3AC1-1
de Greeff A, Reggiori F, Anthony J, Shennan A. The Microlife 3AC1: An accurate blood pressure measurement device in pregnancy and pre-eclampsia J Hypertens 2006; 24 (suppl 4):S279 Abstract P14.475
   
Topouchian JA, El Assad MA, Orobinskaia LV, El Feghali RN, Asmar RG. Validation of two devices for self-measurement of brachial blood pressure according to the International Protocol of the European Society of Hypertension: the Seinex SE-9400 and the Microlife BP 3AC1-1 Blood Press Monit 2005;10:325-331
   
  El Assad M, Topouchian J, Labaki G, Asmar R. Validation of the Microlife BP 3AC1-1 blood pressure measuring device according to the International Protocol of the European Society of Hypertension
 
  El Assad M, Topouchian J, Labaki G, Asmar R. Validation of the Microlife BP 3AC1-1 device for blood pressure measurement according to the International Validation Protocol J Hypertens 2003;[dabl® Educational Trust regrets that full details are missing]
 
  El Assad M, Topouchian J, Labaki G, Asmar R. Validation of the Microlife BP 3AC1-1 device for blood pressure measurement according to the International Validation Protocol American Journal of Hypertension 2003;16:47A
   
 
BP 3AC1-1 PC
  Thompson AM, Eguchi K, Reznik ME, Shah SS, Pickering TG. Validation of an oscillometric home blood pressure monitor in an end-stage renal disease population and the effect of arterial stiffness on its accuracy Blood Pressure Monitoring 2007;12:227-232
 
 
BP 3BTO-A
  Reinders A, Cuckson A C, Lee J T M, Shennan A H. An accurate automated blood pressure device for use in pregnancy and pre-eclampsia: the Microlife 3BTO-A. BJOG 2005;112:1-6
   
  Cuckson A, Reinders A, Shennan A. Validation of the Microlife BP 3BTO-A oscillometric blood pressure monitoring device according to a modified British Hypertension Society protocol
   
 
BP A100 Plus
  Belghazi J, El Feghali RN, Moussalem T, Rejdych M, Asmar RG. Validation of four automatic devices for self-measurement of blood pressure according to the International Protocol of the European Society of Hypertension Vascular Health and Risk Management 2007;3(4):389-400
 
Nais EW284
De Luisignam S, Thiru K. Meredith K, Majeed A, Johnson P. Measuring blood pressure at the wrist: more comfortable for patients and more convenient for doctors? Public Health 2000;114:165-168
 
Nissei
 
Analogue
  O'Brien E, Mee F, Atkins N, O'Malley K.� Inaccuracy of seven popular sphygmomanometers for home-measurement of blood pressure.� J Hypertens 1990;8:621-634
   
 
DS-175
  O'Brien E, Mee F, Atkins N, Thomas M. Evaluation of three devices for self-measurement of blood pressure: according to the revised British Hypertension Society Protocol: the Omron HEM-705CP, Phillips HP5332, and Nissei DS-175. Blood Press Monit �1996;1:55-61
 
NuMed Stabil-O-Graph
Oever GHM ten, Bour J, Cortez-Campeao, van de Kerkhof HM, Wolf A. Validation of Stabil-O-Graph device for self-measurement of blood pressure monitoring according to the British Hypertension Society (BHS) standards and protocol [dabl® Educational Trust regrets that full details are missing] (Abstract)
 
Omron
 
705IT (HEM 759-E)
  Stergiou GS, Yiannes NG, Rarra VC. Validation of the Omron 705 IT oscillometric device for home blood pressure measurement in children and adolescents: The Arsakion School Study Blood Pressure Monitoring 2006,11:229-234
   
Coleman A, Freeman P, Steel S, Shennan A. Validation of the Omron 705IT (HEM-759-E) oscillometric blood pressure monitoring device according to the British Hypertension Society protocol Blood Pressure Monitoring 2006;11:27-32
   
  El Assad M, Topouchian J, Asmar R. Evaluation of two devices for self-measurement of blood pressure according to the international protocol: the Omron M5-I and the Omron 705IT Blood Press Monit 2003;8(3):127-133
   
 
907 (HEM-907/HEM-907-UK)
Amoore JN, Vacher E, Murray IC, Mieke S, King ST, Smith FE, Murray A. Can a simulator that regenerates physiological waveforms evaluate oscillometric non-invasive blood pressure devices? Blood Pressure Monitoring 2006;11:63-67
   
  El Assaad MA, Topouchian JA, Darne BM, Asmar RG Validation of the Omron HEM-907 device for blood pressure measurement. Blood Press Monit 2002;7:237-241
 
  Arita M, Satani Y, Ueno Y, Nishio I. Comparison with casual and automatically measured blood pressure in hypertensive patients - using new developed HEM 907. J Hypertens ?(Abstract)
 
 
HEM-703CP
  Rithalia SVS, Edwards D. Comparison of oscillometric and intra-arterial blood pressure and pulse measurement. J Med Engin Tech 1994;18:179-181.
 
 
HEM-705CP
Graves JW, Grossardt BR, Gullerud RE, Bailey KR, Feldstein J. The trained observer better predicts daytime ABPM diastolic blood pressure in hypertensive patients than does an automated (Omron) device Blood Pressure Monitoring 2006;11:53-58
   
  O'Brien E, Mee F, Atkins N. An accurate automated device for home blood pressure measurement at last!� The Omron HEM-705CP. J Hypertens 1994;12:1317-1318
 
  O'Brien E, Mee F, Atkins N, Thomas M. Evaluation of three devices for self-measurement of blood pressure: according to the revised British Hypertension Society Protocol: the Omron HEM-705CP, Phillips HP5332, and Nissei DS-175. Blood Pressure Monitoring �1996;1:55-61
 
  Artigao LM, Llavador JJ, Puras A, Lopex-Abril J, Rubio MM, Torres C, Vidal A, Sanchi C, Divison JA, Naharro F, Caldevilla D, Fuentes G. Evaluation and validation of Omron Hem 705 CP and Hem 706/711 monitors for self-measurement of blood pressure. 2000.[dabl® Educational Trust regrets that full details are missing.]
 
  Markandu ND, Duneclift S, Carney C, Arnold A. Further evaluation of a semi-automatic blood pressure machine (OMRON HEM-705CP) with an assessment of its use in a hypertension unit and preliminary findings in a general medical ward. J Hum Hypertens 2001;15:357-358 (Abstract)
 
  Czarkowski M, Malgorzata M, Zebrowski M, Baran A, Rozanowski K. Venous blood redistribution alters the accuracy of Omron HEM-705CP. Blood Pressure Monitoring 2004;9:9-12
 
  Furusawa EA, Ruiz MFO, Saito MI, Koch VH Evaluation of the Omron 705-CP blood pressure monitor for use in children and adolescents J Hypertens 2004;22 (suppl 1):S140 (Abstract P510)
 
  Czarkowski M, Mikulska M, Zebrowski M, Baran A, Rozanowski K. Venous blood redistribution alters the accuracy of the Omron HEM-705CP Blood Press Monit 2004;9:9-12
 
  Czarkowski M, Mikulska M, Zebrowski M, Baran A, Rozanowski K. Tilt test alters accuracy of the oscillometric device Omron HEM-705CP J Human Hypertens 2004;18:293-294 (Letter)
 
  El Assad M, Topouchian J, Labaki G, Asmar R. Validation of the Omron 705 IT device for blood pressure measurement according to the international validation protocol American Journal of Hypertension 2003;16:47A
   
 
HEM-706
  Foster C, McKinlay JM, Cruickshank JM, Coats AJS. Accuracy of the Omron HEM 706 portable monitor for home measurement of blood pressure. J Human Hypertens 1994;8:661-664.
   
  Artigao LM, Llavador JJ, Puras A, Lopex-Abril J, Rubio MM, Torres C, Vidal A, Sanchi C, Divison JA, Naharro F, Caldevilla D, Fuentes G. Evaluation and validation of Omron Hem 705 CP and Hem 706/711 monitors for self-measurement of blood pressure. 2000. [dabl® Educational Trust regrets that full details are missing.]
 
 
HEM-711
  Yarrows SA, Brook RD. Measurement Variation Among 12 Electronic Home Blood Pressure Monitors. Am J Hypertens 2000;13:276-282
 
 
HEM-713C
  Mufunda J, Sparks B, Chifomba J, Dakwa C, Matenga JA, Adams JA, et al. Comparison of the Omron HEM-713C automated blood pressure monitor with a standard auscultatory method using a mercury manometer. Central Afr J Med 1996;42:230-232
 
  Afzali B, Abbs IC, Goldsmith D. Automated oscillometric BP devices can significantly overestimate true BP in renal transplant patients. [dabl® Educational Trust regrets that full details are missing.] (Abstract)
 
 
HEM-722C
  C�rdoba R, Fuertes MI, Alvarez A, Molina L, Solans R, Melero I. Validation of a self-monitoring blood pressure monitor: The Omron-HM 722C. Aten Primaria 1997;20:247-250
 
  Bortolotto LA, Henry O, Hanon O, Sikias P, Mourad J-J, Girerd X. Validation of two devices for self-measurement of blood pressure by elderly patients according to the revised British Hypertension Society protocol: the Omron HEM-722C and HEM-735C. Blood Press Monit 1999;4:21-25
 
  Yarrows SA, Brook RD. Measurement Variation Among 12 Electronic Home Blood Pressure Monitors. Am J Hypertens 2000;13:276-282
 
 
HEM-725 CIC
  De Luisignam S, Thiru K. Meredith K, Majeed A, Johnson P. Measuring blood pressure at the wrist: more comfortable for patients and more convenient for doctors? Public Health 2000;114:165-168
 
  Yarrows SA, Brook RD. Measurement Variation Among 12 Electronic Home Blood Pressure Monitors. Am J Hypertens 2000;13:276-282
 
 
HEM-735C
  Bortolotto LA, Henry O, Hanon O, Sikias P, Mourad J-J, Girerd X. Validation of two devices for self-measurement of blood pressure by elderly patients according to the revised British Hypertension Society protocol: the Omron HEM-722C and HEM-735C. Blood Press Monit 1999;4:21-25
 
 
HEM-737 Intellisense
  Anwar YA, Giacco S, McCabe EJ, Tendler BE, White WB. Evaluation of the efficacy of the Omron HEM-737 Intellisense device for use on adults according to the recommendations of the Association for the Advancement of Medical Instrumentation. Blood Press Monit 1998;3:261-26
 
 
HEM-747-IC-N
  Imai Y, Kikuya M, Matsubara M, Araki T, Michimata M, Ohkubo T, Houzawa A, Yamamoto N, Miyawaki Y. Device for self-blood pressure measurements which can monitor blood pressure during sleep. J Hypertens [dabl® Educational Trust regrets that full details are missing.](suppl ?):S25 (Abstract)
 
 
HEM 780REL
  Viera AJ, Hinderliter AL. Validation of the HEM-780REL with easy wrap cuff for self-measurement of blood pressure according to the European Society of Hypertension International Protocol Blood Pressure Monitoring 2007;12:335-338
   
 
M1 Plus (HEM-4011C-E)
  Belghazi J, El Feghali RN, Moussalem T, Rejdych M, Asmar RG. Validation of four automatic devices for self-measurement of blood pressure according to the International Protocol of the European Society of Hypertension Vascular Health and Risk Management 2007;3(4):389-400
   
 
M3 Intellisense (HEM-7051-E)
  Topouchian J, El Feghali R, El Assaad H, Pannier B, Asmar R. Validation of the Omron HEM-7051-E Device for Blood Pressure Measurement According to the International Validation Protocol Journal of Hypertension 2006; 24 (suppl 4) S278
   
 
M4
  Artigao M, Llavador J, Rubio M, Torres C, Lopez J, Sanchis C, Vidal A, Puras A. Evaluation of two devices for self-measurement of blood pressure according to the British Hypertension Society protocol: The Omron M4 and MX2. Am J Hypertens 1998;16:S276 (Abstract only)
 
  Naschitz JE, Loewenstein L, Lewis R, Keren D, Gaitini L, Tamir A, Yeshurun D. Accuracy of the OMRON M4 automatic blood pressure measuring device. J Hum Hypertens 2000;14:423-427
 
 
M5-I (HEM-757-E)
  Omboni S, Riva I, Giglio I, Caldara G, Groppelli A, Parati G. Validation of the Omron M5-I, R5-I and HEM-907 automated blood pressure monitors in elderly individuals according to the International Protocol of the European Society of Hypertension Blood Pressure Monitoring 2007;12:233-242
   
  El Assad M, Topouchian J, Labaki G, Asmar R. Validation of the Omron M5-I device for blood pressure measurement according to the international validation protocol
 
  El Assad M, Topouchian J, Asmar R. Evaluation of two devices for self-measurement of blood pressure according to the international protocol: the Omron M5-I and the Omron 705IT Blood Press Monit 2003;8(3):127-133
 
 
M6 (HEM-7001-E)
  Altunkan S, Iliman N, Kayaturk N, Altunkan E. Validation of the Omron M6 (HEM-7001-E) upper-arm blood pressure measuring device according to the International Protocol in adults and obese adults Blood Pressure Monitoring 2007;12:219-225
   
  Altunkan S, Iliman N, Kayaturk N, Altunkan E. Validation of the Omron M6 upper arm blood pressure measuring device according to the International Protocol in adults. J Hypertens 2006; xx (suppl x):213 (Abstract PO1-43)
   
Topouchian JA, El Assaad MA, Orobinskaia LV, El Feghali RN, Asmar RG. Validation of two automatic devices for self-measurement of blood pressure according to the International Protocol of the European Society of Hypertension: the Omron M6 (HEM-7001-E) and the Omron R7 (HEM 637-IT) Blood Press Monit 2006; 11 :165-171
   
 
M6 Comfort (HEM-7000-E)
  Belghazi J, El Feghali RN, Moussalem T, Rejdych M, Asmar RG. Validation of four automatic devices for self-measurement of blood pressure according to the International Protocol of the European Society of Hypertension Vascular Health and Risk Management 2007;3(4):389-400
   
 
M7 (HEM-780E)
  El Feghali RN, Topouchian JA, Pannier BM, El Assaad HA, Asmar RG. Validation of the Omron M7 (HEM-780-E) blood pressure measuring device in a population requiring large cuff use according to the International Protocol of the European Society of Hypertension Blood Pressure Monitoring 2007;12:173-178
   
  Coleman A, Steel S, Freeman P, de Greeff A, Shennan A. Validation of the Omron M7 (HEM-780-E) oscillometric blood pressure monitoring device according to the British Hypertension Society protocol. Blood Pressure Monitoring 2008;13:49-54
   
 
MX2
  Artigao M, Llavador J, Rubio M, Torres C, Lopez J, Sanchis C, Vidal A, Puras A. Evaluation of two devices for self-measurement of blood pressure according to the British Hypertension Society protocol: The Omron M4 and MX2. Am J Hypertens 1998;16:S276 (Abstract only)
 
 
MX3 Plus
Coleman A, Freeman P, Steel S, Shennan A Validation of the Omron MX3 Plus oscillometric blood pressure monitoring device according to the European Society of Hypertension international protocol Blood Press Monit 2005; 10 :165-168
 
Oregon Scientific BPW810
Li L, Wang Hui W, Jin Lan W. Validation of the Oregon Scientific BPW810 blood pressure monitor according to the European Society of Hypertension Protocol. Blood Press Monit 2006;11:343-347
 
Phillips HP5308, HP5306/B, HP5332
O'Brien E, Mee F, Atkins N, O'Malley K.� Inaccuracy of seven popular sphygmomanometers for home-measurement of blood pressure.� J Hypertens 1990;8:621-634
 
O'Brien E, Mee F, Atkins N, Thomas M. Evaluation of three devices for self-measurement of blood pressure: according to the revised British Hypertension Society Protocol: the Omron HEM-705CP, Phillips HP5332, and Nissei DS-175. Blood Pressure Monitoring �1996;1:55-61
 
Rossmax
O'Brien E, Atkins N, Murphy A, Lyons S. Validation of the Rossmax blood pressure measuring monitor according to the European Society of Hypertension International Protocol for validation of blood pressure measuring devices in adults Blood Press Monit 2003;8:261-265
 
Rossmax ME 701 Series
de Greeff A, Shennan AH. The Rossmax (ME 701 series) upper arm device: accuracy assessment in an adult population according to the International and the British Hypertension Society protocols Blood Pressure Monitoring 2008;13:43-48
 
Seinex SE-9400
Topouchian JA, El Assad MA, Orobinskaia LV, El Feghali RN, Asmar RG. Validation of two devices for self-measurement of brachial blood pressure according to the International Protocol of the European Society of Hypertension: the Seinex SE-9400 and the Microlife BP 3AC1-1 Blood Press Monit 2005;10:325-331
 
Sensacare SAA-102
Zaetta V, Daniele L, Perkovic D, Prattico F, Barisa M, Perfetti P, Gabrieli A, Buonocore F, Winnicki M. Validation of the SAA-102 home blood pressure monitor according to the protocols of the European Society of Hypertension, the Association for the Advancement of Medical Instrumentation and the British Society of Hypertension Blood Pressure Monitoring 2007;12:363-368
 
Spengler KP7500D
Belghazi J, El Feghali RN, Moussalem T, Rejdych M, Asmar RG. Validation of four automatic devices for self-measurement of blood pressure according to the International Protocol of the European Society of Hypertension Vascular Health and Risk Management 2007;3(4):389-400
 
Sunbeam7623
Yarrows SA, Brook RD. Measurement Variation Among 12 Electronic Home Blood Pressure Monitors. Am J Hypertens 2000;13:276-282
 
Systema Dr MI-150
O'Brien E, Mee F, Atkins N, O'Malley K.� Inaccuracy of seven popular sphygmomanometers for home-measurement of blood pressure.� J Hypertens 1990;8:621-634
 
Terumo ES-H51
Yarrows SA, Brook RD. Measurement Variation Among 12 Electronic Home Blood Pressure Monitors. Am J Hypertens 2000;13:276-282
 
Visomat OZ2
Dieterle T, Battegay E, Bucheli B, Martina B. Accuracy and ‘range of uncertainity’ of oscillometric blood pressure monitors around the upper arm and wrist. Blood Press Moni 1998;3:339-346
 
Welch Allyn Transtelephonic Home Blood Pressure Monitor
Herbst T, Anis-Anwar Y, Giacco S, White W. Evaluation of the overall system precision of the Welch-Allyn transtelephonic home blood pressure monitor in adults with Parkinson's disease. Blood Press Monit 2002;7:285-288
 

Wrist Devices for Self Measurement

A&D UB-511
Angeli F, Sardone M, Angeli E, Repaci S, Gattobigio R, Verdecchia P. Validation of the A&D wrist-cuff UB-511 (UB-512) device for self-measurement of blood pressure. Blood Press Monit 2006; 11 :349-354
 
Assure A30/BD-W 20
Yarrows SA, Brook RD. Measurement Variation Among 12 Electronic Home Blood Pressure Monitors. Am J Hypertens 2000;13:276-282
 
Boso-Mediwatch
(See Specific Ambulatory Sphygmomanometers for Continuous Measurement for later references)
Rogers P, Burke V, Stroud P, Puddey IB. Comparison of oscillometric blood pressure measurements at the wrist with an upper-arm auscultatory mercury sphygmomanometer Clin & Exper Pharmacol & Pharmacol 1999;26:477-481
 
Braun
 
Braun BP 3550
  Iliman N, Altunkan S, Kayaturk N, Altunkan E. Validation of the Braun BP 3550 wrist blood pressure measuring device with a position sensor and an EasyClick cuff according to the International Protocol in adults. Blood Pressure Monitoring 2007;12:45-49
   
 
BP 3000
Nolly H, Romero M, Nolly A, Silva M, Nolly M. Clinical evaluation of the Braun BP 3000 Easy Click according to the ANSI/AAMI SP 10:2002 Blood Pressure Monitoring 2006;11:91-95
   
 
PrecisionSensor 2000
  Wessig K, Hollinger S, Schmalzhaf I, Lenz T. Clinical evaluation of the efficacy of the Braun PrecisionSensor oscillometric wrist blood pressure monitor for use on adults versus auscultation as deficned by ANSI/AAMI SP 10-1992. Blood Pres Monit 2000;5:239-245
   
  Grassi G, Foglia G, Dell'Oro R, Seravalle G, Boari G, Mancia G. Reproducility of home blood pressure monitoring by a new oscillometric wrist automatic device. J Hypertens 2001; 19 (suppl 2):S22
   
  Nolly H, Osso A, Romero M, Nolly M. The reproducibility of home-self measurements using the Braun PrecisionSensor BP 2550 Monitor. J Hypertens 2001;19 (suppl 2):S26 (Abstract)
   
  Nolly H, Osso A, Romero M, Nolly A. Home Blood Pressure Monitoring: Validation of the Braun BP 2550 Equipment. AJH �2002;15:83A (Abstract)
   
  Nolly H, Osso A, Nolly A, Romero M, Nolly M. Usefullness of home blood pressure determination: validation of� the Braun BP 2550 Equipment. J Hypertens 2002;20 (suppl 4):S238
   
  Uen S, Weisser B, Wieneke P, Vetter H, Mengden T. Evaluation of the Performance of a Wrist Blood Pressure Measuring Device With a Position Sensor Compared to Ambualatory 24-Hour Blood Pressure Measurements. Am J Hypertens 2002;15:787-792
 
 
PrecisionSensor BP2550 and BP2550 (UG)
  Sandevik E, Dyrdal A. Evaluation of the Braun BP2550 PrecisionSensor wrist blood pressure monitor in clinical practice[dabl® Educational Trust regrets that full details are missing]
 
  Nolly H, Raposo I, Nolly A. Accuracy of the Braun BP2550 (UG) device in home blood pressure measurement[dabl® Educational Trust regrets that full details are missing]
 
  Nolly H, Romero M, Nolly A, Osso P, Reinoso O, Nolly M. Home blood pressure measurement: validation of the Braun BP 2550 (UG) monitor according to the ESH International Protocol Blood Press Monit 2004;9:53-58
 
  Nolly H, Osso P, Nolly M. Home blood pressure monitoring Intercontinental Cardiology 2001;10:111-114
   
  Nolly H, Osso A, Romero M, Nolly M. The reproducibility of home- self measurements using the Braun PrecisionSensor BP 2550 Monitor J Hypertens 2001;19 (suppl 2):S26
 
 
Vital Scan
  Nolly H, Romero M, Nolly A, Nolly M. Home blood pressure (BP) measurement using B.P. Braun Vitalscan monitor. J Hypertens 200;18(supp 4):S119 (Abstract)
 
Klock
Zweiker R, Schumacher M, Fruhwald FM, Watzinger N, Klein W. Comparison of wrist blood pressure measurement with conventional sphygmomanometry at a cardiology clinic. J Hypertens 2000;18:1013-1018
 
Microlife
 
 
BP 3BU1-5
  Altunkan S, Iliman N, Altunkan E. Validation of the Samsung SBM-100A and Microlife BP 3BU1-5 wrist blood pressure measuring devices in adults according to the International Protocol Blood Pressure Monitoring 2007;12:119-125
 
 
BP W200-1
  Palatini P, Dorigatti F, Bonso E, Ragazzo F. Validation of the Microlife BP W200-1 wrist device for blood pressure measurement. Blood Press Monit 2008;13:295-298
 
Nais
Caridi G, Zoccali C, Enia G. The oscillometric wrist devices: an estimate of the 'supine' error. J Human Hypertens 2002;16:525-526
 
Nissei WS-310
Altunkan Ş, Yildiz SA. Wrist blood pressure measuring devices: a comparitive study of the accuracy with a standard auscultatory method using a mercury sphygmomanometer. J Hypertens [dabl® Educational Trust regrets that full details are missing.](suppl ?):S25 (Abstract)
 
Omron
 
HEM-601
  Yarrows SA, Brook RD. Measurement Variation Among 12 Electronic Home Blood Pressure Monitors. Am J Hypertens 2000;13:276-282
 
 
HEM-605
  Yarrows SA, Brook RD. Measurement Variation Among 12 Electronic Home Blood Pressure Monitors. Am J Hypertens 2000;13:276-282
 
 
HEM-608
  Shennan AH, Rushbrook J, Power J, Wright J, Poston L An accurate oscillometric wrist blood pressure monitor: validation of the Omron Rx [HEM-608]. J Human Hypertens 1998;12:794
 
 
HEM-637IT
Altunkan Ş, Öztas K, Altunkan E. Validation of the Omron 637IT wrist blood pressure measuring device with a position sensor according to the International Protocol in adults and obese adults Blood Press Monit 2006;11:79-85
   
Altunkan Ş, Altunkan E. Validation of the Omron 637IT wrist blood pressure measuring device with a position sensor according to the International Protocol in the elderly Blood Press Monit 2006;11:97-102
   
  Altunkan Ş, Iliman N, Altunkan E Accuracy of the new wrist blood pressure monitor (Omron 637 IT), for blood pressure measurement J Hypertens June 2003;21(Suppl.4):S22
 
  Yarrows SA. Comparison of the Omron HEM-637 wrist monitor to the auscultation method with the wrist position sensor on or disabled Americam Journal of Hypertension 2004;17(No 1) 54:58
 
  Yarrows SA. Comparison of the Omron HEM-637 wrist monitor to the ausculatation method with the wrist position sensor on or disabled Am J Hypertens 2004;17:54-58
 
 
HEM-804F
  Yarrows SA, Brook RD. Measurement Variation Among 12 Electronic Home Blood Pressure Monitors. Am J Hypertens 2000;13:276-282
 
 
IC HEM-725CIC
  De Luisignam S, Thiru K. Meredith K, Majeed A, Johnson P. Measuring blood pressure at the wrist: more comfortable for patients and more convenient for doctors? Public Health 2000;114:165-168
 
 
R3
  Eckert S, Gleichmann U, Zagorski O, Klapp A. Validation of the Omron R3� blood pressure self-measuring device through simultaneous comparative invasive measurements according to protocol 58130 of the German Institute for Validation. Blood Pressure Monitoring 1997;2:189-192
 
  Yarrows SA, Brook RD. Measurement Variation Among 12 Electronic Home Blood Pressure Monitors. Am J Hypertens 2000;13:276-282
 
  Eckbert S, Kemper B, Horstkotte D. How accurate are devices for blood pressure self-measurement at the upper arm, wrist and finger in young normotensive patients and elder hypertensive patients? J Hypertens 2001;19(suppl 2):S24 (Abstract)
 
 
R5-I
  Omboni S, Riva I, Giglio I, Caldara G, Groppelli A, Parati G. Validation of the Omron M5-I, R5-I and HEM-907 automated blood pressure monitors in elderly individuals according to the International Protocol of the European Society of Hypertension Blood Pressure Monitoring 2007;12:233-242
   
 
R7
  Topouchian JA, El Assaad MA, Orobinskaia LV, El Feghali RN, Asmar RG. Validation of two automatic devices for self-measurement of blood pressure according to the International Protocol of the European Society of Hypertension: the Omron M6 (HEM-7001-E) and the Omron R7 (HEM 637-IT) Blood Press Monit 2006;11:165-171
   
 
RX, RX-M, RX2
  Zambanini A, Cox A, McIntosh C, Feher M. A comparison of semi-automated BP monitors in diabetic patients. J Hypertens 2000;18(suppl 4):S121 (Abstract)
 
  Altunkan Ş, Yildiz SA. Wrist blood pressure measuring devices: a comparitive study of the accuracy with a standard auscultatory method using a mercury sphygmomanometer. J Hypertens [dabl® Educational Trust regrets that full details are missing.](suppl ?):S25 (Abstract)
 
  Longo D, Bertolo O, Toffanin G, Frezza P, Palatini P. Validation of the A & D UA-631 (UA-779 Life Source) device for self-measurement of blood pressure and relationship between its performance and large artery compliance. Blood Press Monit 2002;7:243-248
 
  Artigao LM, Llavador JJ, Puras A, Lopex-Abril J, Rubio MM, Torres C, Vidal A, Sanchi C, Divison JA, Naharro F, Caldevilla D, Fuentes G. Evaluation and validation of Omron Hem 705 CP and Hem 706/711 monitors for self-measurement of blood pressure. 2000.[dabl® Educational Trust regrets that full details are missing]
   
  Shennan AH, Rushbrook J, Power J, Wright J, Poston L. An accurate oscillometric wrist blood pressure monitor: validation of the Omron Rx [HEM-608] J Human Hypertens 1998;12:794 (Abstract)
   
  Braam R, Aslan B, Thein T. Accuracy of the Omron RX-M, an automated wrist blood pressure measuring device J Hypertens 2003;[dabl® Educational Trust regrets that full details are missing] (Abstract)
   
  Braam R, Aslan B, Thein T. Accuracy of the Omron RX-M, an automated blood pressure measuring device, measureing blood pressure at the wrist, according to a modified British Hypertension Society protocol Blood Press Monit 2004;9:25-30
   
  Cuckson AC, Moran P, Seed P, Reinders A, Shennan AH. Clinical evaluation of an automated blood pressure wrist device Blood Press Monit 2004;9:31-37
   
 
RX3
  El-Assaad MA, Orobinskaya LV, Topouchian JA, Asmar RG. Validation of the Omron® RX-3 Blood Pressure Measuring Device at the wrist level according to the International Protocol of the European Society of Hypertension AJH 2005;18(No. 5, Part 2):29A (P58)
 
Samsung SBM-100A
Altunkan S, Iliman N, Altunkan E. Validation of the Samsung SBM-100A and Microlife BP 3BU1-5 wrist blood pressure measuring devices in adults according to the International Protocol Blood Pressure Monitoring 2007;12:119-125
 
Sensacare SAW-102
Zaetta V, Longo D, Perkovic D, Prattico F, Barisa M, Perfetti P, Gabrieli A, Buonocore F, Winnicki M. Performance of the SAA-I02 and of the SAW-102, Arm and Wrist Blood Pressure Monitors, According to the Protocols of the European Society of Hypertension, Association for the Advancement of Medical Instrumentation and British Society of Hypertension Journal of Hypertension 2006;25 (suppl 2)
 
Sunbeam7654
Yarrows SA, Brook RD. Measurement Variation Among 12 Electronic Home Blood Pressure Monitors. Am J Hypertens 2000;13:276-282
 

Finger Devices for Self-measurement

Lumoscope 1085M
Yarrows SA, Brook RD. Measurement Variation Among 12 Electronic Home Blood Pressure Monitors. Am J Hypertens 2000;13:276-282
 
Marshall F-88
Yarrows SA, Brook RD. Measurement Variation Among 12 Electronic Home Blood Pressure Monitors. Am J Hypertens 2000;13:276-282
 
National Ltd. EW276H
Yarrows SA, Brook RD. Measurement Variation Among 12 Electronic Home Blood Pressure Monitors. Am J Hypertens 2000;13:276-282
 
Omron
 
B15
  Yarrows SA, Brook RD. Measurement Variation Among 12 Electronic Home Blood Pressure Monitors. Am J Hypertens 2000;13:276-282
 
 
F3
  Eckbert S, Kemper B, Horstkotte D. How accurate are devices for blood pressure self-measurement at the upper arm, wrist and finger in young normotensive patients and elder hypertensive patients? J Hypertens 2001;19(suppl 2):S24 (Abstract)
 
 
HEM-812F
  Yarrows SA, Brook RD. Measurement Variation Among 12 Electronic Home Blood Pressure Monitors. Am J Hypertens 2000;13:276-282
 

Devices for Measuring Blood Pressure in the Community

A&D TM-2655
Kobalava ZD, Kotovskaya YV, Babaeva LA, Moiseev VS. Validation of oscillometric device for blood pressure measurement Blood Pressure Monitoring 2006;11:87-90
 
Keito
Staal EM, Nygard OK, Omvik P, Gerdts E. Blood pressure measurements by the Keito machine. Evaluation versus office blood pressure by physicians Blood Press Monit 2004;9:167-172
 
Pharma-Smart PS-2000
Alpert BS. Validation of the Pharma-Smart PS-2000 public use blood pressure monitor Blood Press Monit 2004;9:19-23
 
Vita-Stat
Nara AR. Performance Review of a Noninvasive Blood Pressure Monitor. Medical Electronics 1996;27:63-67
 